top of page

Product Overview

maestro33.jpg

EXTENSIVE SET OF REPORTS
The Maestro2 provides rich analysis functions for the Macula and Glaucoma. Comprehensive, predefined reports can be quickly printed or sent to your image management system.

5 LINE CROSS SCAN
5 line cross scan (6mm, 9mm) both horizontal and vertical in an instant.

3D WIDE SCAN (12mm x 9mm)
This scan provides images of the macula and optic nerve in one report, providing retina, RNFL, and GCL analysis. Reference database of the RNFL, GCL+, GCL++, and total retina are automatically generated.

3D DISC ANALYSIS
Combines disc topography, fundus photography, various peripapillary parameters and RNFL thickness measurements. The reference database for RNFL and disc parameters is also incorporated.

Integrated full-color fundus camera. With one touch, you can acquire a posterior OCT image and a true color fundus image. This allows PinPoint Registration and structural confirmation of the pathology. Small pupil function is also available, as well as fundus only capture. 
 

TRUE COLOR* FUNDUS PHOTOGRAPHY

PERIPHERAL FUNDUS PHOTOGRAPHY
The Maestro2 allows the operator to automatically select 9 standard fields or manually manipulate the patient’s fixation to create a mosaic image with the AutoMosaic software.

LIVE FUNDUS VIEW™ 
OCT-LFV is a live projection image of the retina. The clear live fundus image makes the disc, retinal vessels and scanning position easy to see, when required. 

CATARACT MODE
Cataract mode automatically moves the scanning position on the upper/lower area to adjust for  opacity in the eye due to cataract.

HIGH RESOLUTION OCT AND COLOR FUNDUS PHOTOGRAPHY
A high-resolution B-scan and smooth 3D graphics facilitate the observation of pathology and each layer of the retina.

High-quality color fundus photography gives fundamental and additional information. The OCT and color fundus are an inseparable combination for daily diagnosis. 

85-years old, male, OD, Branch Retinal Vein Occlusion (BRVO)

62-years old, male, OS, Diabetic Retinopathy (DR) and circinate exudate

97-years old, female OD, Age-Related Macular Degeneration
(AMD)

66-years old, male OS, macular hole (full thickness)

Topcon 3D OCT-1 Maestro 2

Introducing a fully automated OCT

 

At the touch of a button, the Maestro2 provides instantaneous structural information in easy to interpret formats, along with true color* fundus imaging and pin point registration.

With the Maestro2, you have fast, multi-modality OCT/Fundus imaging, and advanced data management. The complete clinical workstation for any busy practice.

Fully Automated and Fully Loaded

With the Maestro2, you have fast, multi-modality OCT/Fundus imaging, and advanced data management.  The complete clinical workstation for any busy practice.

Introducing fully automated OCT. At the touch of a button, the Maestro2 provides instantaneous structural information in easy to interpret formats, along with true color* fundus imaging and pin point registration.

Features:

  • true color fundusCombination OCT and 

  • Compact and space saving design

  • The NEW Hood Report for Glaucoma

  • Reference database for retina, RNFL, GCL+, and GCL++ Thickness

  • Automatic layer segmentation

  • Widefield OCT

  • Anterior segment OCT

  • Panoramic fundus imaging

THE MAESTRO2

A most user-friendly OCT. With one touch of the screen, auto alignment, auto focus and auto capture is activated. 

FULL-AUTO CAPTURING 
With a single touch, the Maestro2 automatically performs alignment, focus, optimizing and capturing. After capturing, the report can be immediately displayed by clicking on the icon. 
MANUAL/SEMI-AUTO CAPTURING 
In addition to automated capture, the Maestro2 offers manual/semi-manual options for difficult-to-image
patients.

Select a

capture icon

Adjust the chinrest position and touch [Start CAPTURE]

Instant results 

are displayed

Report can be displayed immediately

maestro44.jpg

The Maestro2 can capture a 12mm x 9mm widefield OCT scan, encompassing both the macula and disc. Ideal for an annual eye exam, this scan reduces patient testing time. It provides thickness and reference data for the retina, RNFL, GCL+, and GCL++ together with Disc topography including automated LCDR values.

WIDEFIELD OCT SCAN 

THE HOOD REPORT FOR GLAUCOMA AND PROBABILITY MAPS 

with 3D Wide 12x9mm Scan 
Retinal Thickness/RNFL/GCL and Optic Nerve Metrics in just one fast scan. The The Hood Report for Glaucoma is now available. This innovative report simplifies and accelerates 
the decision-making process through the correlation of structure (GCC/RNFL) with function (overlay of Visual Field test locations).

ANTERIOR SEGMENT CALIPER/ANGLE ANALYSIS

The Maestro2 has the added advantage of Anterior OCT scanning capability, without the need for an additional expensive/delicate lens. By simply adding the anterior headrest support, the Maestro2 is able to capture corneal 
and chamber angle scans together with the ability to make corneal thickness and angle measurements using the integrated caliper tools. Dry eye tear meniscus can also be visualized/measured together.